Consumer Daily Hainan Cancer Hospital completed the first digestive endoscopic robotic surgery in Hainan
China News China News Service Health | Can the heart also "lose its strength"? Experts elaborate on the early warning, prevention, and treatment of heart failure
Hainan Daily Hainan's First Digestive Endoscopy Robot Surgery Successfully Implemented
China News Net Hainan Hainan Cancer Hospital implements digestive endoscopy robotic surgery for precise treatment of early esophageal cancer
Phoenix News National Gastric Cancer Awareness Day | Hainan ranks among the top five in terms of gastric cancer incidence rate; experts interpret diet-related risks and early screening strategies
People's Daily Online: Experts from Hainan Provincial Cancer Hospital Preventing and treating lung cancer hinges on "strategic advancement", with early detection achieving a cure rate of up to 90%
hinews.cn Hainan's First Digestive Endoscopy Robot Surgery Successfully Implemented
Haiba News Hainan's First Digestive Endoscopy Robot Surgery Successfully Implemented
Tropical News Donating 4,000 "Huiqiongbao" Insurance Policies to Provide Shelter for Impoverished Patients
Consumer Daily Hainan Cancer Hospital Commences Construction of International Proton Therapy Center, Filling the Regional Technical Gap

1. Device Technical Features and Performance
(1) Magnetic Field Strength: 3.0T
(2) Magnet Bore Diameter: 70cm
(3) The system employs a uRF ultra-high-speed RF transmission system, ACG 3D self-calibrating gradient system, DMS ultra-high-speed receiving RF coil, and the innovative SRE Snap Reconstruction Engine hardware platform, which enables micro-gradient dynamic switching and rapid continuous RF transmission/receiving. This setup, combined with the unique 3D SPA spiral acquisition technology, eliminates gradient noise, enhances image quality, and shortens scan times.
(4) Equipped with a magnetic resonance-guided focused ultrasound device for therapeutic use.
2. Clinical Application of the Device
(1) Silent MR - 3D Arterial Spin Labeling Imaging: No contrast agent is required. A single scan provides full brain perfusion imaging, allowing measurement of cerebral blood flow in specific regions.
(2) Silent MR - Multi-contrast Diffusion Imaging: Offers up to 40 selectable B-values for more accurate ADC values, isotropic tetrahedral acquisition, shorter scan times, higher signal-to-noise ratios, and cleaner background images.
(3) SilenZ Contrast Imaging Package
(4) Paired with a focused ultrasound device for the treatment of uterine fibroids.
3. Department Using the Equipment
Medical Imaging Department.